KabinPLUS AISLE CONTAINMENT SOLUTIONS

KabinPLUS AISLE CONTAINMENT SOLUTIONS

To increase the "Energy Efficiency" and manage the "Physical Security & Access Control" in data center environments, KabinPLUS offers Data Center Aisle and Containment Solutions.

Please click for download the catalogue

Energy Efficiency

The accelerated rise of energy consumption in data centers and inreasing global energy costs make the energy efficiency the permament hot topic in the data center industry. Due to its big impact on energy efficiency, cooling methods shall be considered and implemented carefully according to the type of IT infrastructure. The main purpose shall be to completely isolate cold cooling air and hot exhaust air with a correct airflow management and applying containment solutions of cold air exhaust air.

Aplications
Reduce Energy Consumption
  • Improve Airflow
  • Secure Physical Access
  • Dedicated Containment
  • Separate Cold and Hot Air
  • Improve Overall Hardware Equipment Efficiency
  • Space Management for Non-Standard Rows
  • Room & Space & Cabinets Zoning

Energy-Efficiency-Data-Center-1089

Physical Security & Access Control

Rack Cabinet, corridor, room, zone and building based physical and environmental security against theft, fire, flood and earthquake shall be maintained and the access to the related zones shall be supervised in data center environments.
Cold-Aisle-Containment-(CAC)
Particular Zoning Solutions
  • Particularly designed frames
  • Vertical Space & Room Zoning
  • Integrated Cabinet Zoning
  • Partition
Integrated Physical Security
  • Integrated Physcial Security
  • Sliding and folding doors designed to enable physical security for a certain zone of cabinets

Aisle Containment Solution - Cold Aisle

Cold Aisle Containment for rack cabinets with single or double sliding doors and sliding roof frame units made of aluminum with polycarbonate panel material and fire nozzle entry sections.

Thanks to the specially designed fixing and flexible plastic isolation elements, the hot aisle chimney can easily be levelled and installed on top of the cabinets ensuring a flexible containment and airflow separation.

Cold-Aisle-Containment-35937

Non-Standart Cabinets Containment

Cold Aisle Containment- for Data Center

Adjustable to various cabinet heights and widths, dummy elements can be deployed to unused cabinet spaces for partition ensuring flexibility and modularity for future growth as well as for the existing non-standard sized rack cabinets&server hardware. Specially designed seismic stands are applied below the raised floor together with the dummy aluminium&polycarbonate frames adjustable to different heights to accommodate non-standard rack cabinets in different dimensions.

Seismic Stand

Seismic stands ensure an independent platform from day 1 for the existing and future rack cabinet installations as well as for non-standard cabinet rows.

Seismic-Stand-for-Data-Centre

Aisle Containment Solution - Hot Aisle

Hot Aisle Containment-1089

To ensure hot and cold air insulation to increase energy efficiency in suspended ceiling data center environments, an open chimney system to form the "Hot Aisle" made of aluminum frames with polycarbonate material is utilised where the hot air is directed to the plenum area.

Thanks to the specially designed fixing and flexible plastic isolation elements, the hot aisle chimney can easily be levelled and installed on top of the cabinets ensuring a flexible containment and airflow separation.

K-BAR
Containment Corridor Linear LED Lighting Luminaire

  • Operation Temperature: -20˚/+50˚C
  • Light Source: Chip LED
  • Light Color: Natural White (3800-4200 K)
  • Beam Angle: 120˚ without lens
  • Light Efficacy: 105 lm/W
  • Operation Voltage: 100-240V 50/60Hz.
  • Power Consumption (W): 10W/m
Led Lighting for Data Center
Data-Center-Lighting-1359